Salt-air corrosion: protecting air conditioning and refrigeration in Camps Bay

Camps Bay properties sit in one of the most corrosive domestic environments in Cape Town. Onshore wind carries fine salt particles inland, they settle on any surface facing the sea, and the combination of salt, moisture and warm metal starts a corrosion cycle that quietly reduces the performance of air conditioning and refrigeration equipment. Nothing prevents it completely. What changes is how quickly it progresses, and how much it costs when it finally causes a failure.

What salt actually does to a unit

The condenser coil is the most exposed component. Its aluminium fins are thin by design so that air can pass between them, which also means a salt film sits directly on the metal. Once the protective oxide layer is disturbed, pitting begins at the fin edges. Pitted fins no longer transfer heat efficiently, so the compressor runs longer to achieve the same cooling. The unit sounds normal while it slowly loses capacity.

Steel follows a different path. Fan guards, screws, brackets and cabinet seams rust, and rust expands. That expansion can crack powder coating, loosen a mounting point or seize a screw that later has to be drilled out during a repair. Electrical terminals and control boards are affected too: salt film is conductive and hygroscopic, which is why intermittent faults and corroded plugs show up on older coastal installations.

Which positions are worst

Distance from the sea matters, but exposure matters more. A unit tucked under a deep eave on the mountain side of a house can outlast one on an open sea-facing wall at the same address. The harshest positions are those that face the prevailing onshore wind, sit low where sea mist settles, or receive spray from a pool or irrigation system. Roof-mounted plant is exposed to wind-driven salt and usually has the least shelter.

When we assess a site, we look at prevailing wind, roof overhangs, the presence of a windbreak, and how easily the unit can be rinsed. Moving an outdoor unit a metre or two into shelter, or lifting it clear of ground splash, often does more for its life than any additive or coating.

The routine that makes a measurable difference

Rinsing is the single most useful habit. Fresh water, applied gently to the coil and casing, removes salt before it can concentrate. A garden hose on a low setting is enough; high pressure bends fins and drives water into places it should not go. Frequency depends on exposure, but monthly during the windy summer months is a sensible starting point for exposed units, and quarterly for sheltered ones.

Beyond rinsing, keep the area around the unit clear so air can move. Salt plus trapped leaves and dust creates a mat that holds moisture against the coil. Have the coil chemically cleaned during a service rather than relying on water alone, and have loose fixings replaced with stainless or coated equivalents before they seize.

  • Rinse the coil and casing with fresh water monthly in exposed positions
  • Keep at least the manufacturer's clearance around the unit, free of stored items
  • Replace rusted screws, brackets and fan guards before they fail
  • Have coils cleaned properly at each service, not just hosed down
  • Check electrical terminals and plugs for green corrosion during servicing
  • Note any paint damage on the cabinet and treat it early

Protective coatings and marine-grade hardware

Coatings help, and they are worth considering on new equipment in exposed positions, but they are not permanent. A coating that is scratched or worn in one place becomes a starting point for corrosion underneath, which can be worse than no coating because the damage is hidden. Coatings need to be inspected at service and renewed when they break down.

Marine-grade stainless fixings and brackets are a straightforward improvement on exposed installations. They cost a little more and last considerably longer than standard zinc-plated hardware in salt air.

When corrosion means replacement

There is a point where repair stops making sense. If the coil fins crumble when touched, if the casing has rusted through, or if refrigerant leaks keep returning at corroded joints, further repairs are money spent on a failing shell. We would rather show you the condition and explain the options than keep charging for callouts.

The practical message is that coastal equipment needs a maintenance relationship, not a single installation. A unit that is rinsed, cleaned and inspected twice a year will generally give noticeably longer service than an identical unit that is only looked at when it stops working.

Key points

  • Salt film on condenser fins reduces capacity before it causes a visible fault
  • Exposure and siting matter more than distance from the sea
  • Monthly fresh-water rinsing and six-monthly servicing are the core routine
  • Coatings and marine-grade fixings help but need inspection
  • Crumbling fins or repeat leaks usually signal replacement, not another repair

Next step

Tell us what the system is doing